WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations readily
accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to sun
light. To reduce risk of injury while installing, servicing or clean-
ing unit, cover the solar panel with cardboard or disconnect the
wires from the motor terminals (note wire locations when discon-
necting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these in-
takes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a light
spray of rain into this attic space. This is a normal condition with
all attic ventilators and will not cause any damage to the struc-
ture. We recommend that you do not store any valuable articles
directly under the fan opening in the roof.
7. This ventilator is intended for roof installation. Broan Models 353,
345GOBK & 345GOWW Gable Mount Ventilators are available
for side wall applications.
8. The plastic ventilator dome and base may be painted with high
quality paint. Follow the paint manufacturer's recommendations
for acrylic and ABS plastic as appropriate. Take care to avoid
getting paint on the solar panel.
9. This ventilator includes a permanently lubricated motor. Do not
oil or disassemble.
10. The installation instructions contained in this document are only
a recommendation and individual professionals may have their
own methods of installation. If your roof has an existing warranty,
installation of this product by anyone other than those who in-
stalled the roof may jeopardize any future warranty claim. Please
check with the original installer of your roof if this is a concern.
11. When working with asphalt shingles in cold weather (below
40
o
F), take care to avoid damage to the shingle edges and cor-
ners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
o
F. Power is applied to the motor when the temperature
reaches 61
o
F.
ROOF-MOUNT REMOTE
SOLAR POWERED
ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
r
Slotted Screwdriver
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Pry Bar (to remove roofing nails)
r
5/16" Socket and Extension
r
Roofing Cement
r
Galvanized Roofing Nails (1¾" min.)
TOOLS AND MATERIALS REQUIRED
Register your product online at:
www.broan.com/register
Vue de la page 0
1 2 3 4 5 6 ... 23 24

Résumé du contenu

Page 1 - ATTIC VENTILATOR

MODELS 345RSOBK • 345RSOWWPage 1WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this uni

Page 2

MODÈLES 345RSOBK • 345RSOWWPage 105. De l'intérieur du grenier, trouvez l'endroit voulu et marquez un point à mi-chemin entre deux chevro

Page 3 - MODELS 345RSOBK • 345RSOWW

MODÈLES 345RSOBK • 345RSOWWPage 118. Coupez les bardeaux à l'intérieur du cercle.9. En utilisant toujours l'avant-trou de l’étape 6 comm

Page 4

MODÈLES 345RSOBK • 345RSOWWPage 1214. Assurez-vous que la base du ventilateur est parallèle à la ligne du faîte, soulevez délicatement les bardeaux

Page 5 - REMOTE SOLAR PANEL

MODÈLES 345RSOBK • 345RSOWWPage 131 7. De l'intérieur du grenier, trouvez le centre de l'emplace-ment choisi à l'étape 2 pour le pann

Page 6 - SERVICE PARTS

MODÈLES 345RSOBK • 345RSOWWPage 14Modèle Modèle Repère 345RSOBK 345RSOWW Description (noir) (bois intempérisé) 1 77001317 77001318 Ensembl

Page 7 - WARRANTY

MODÈLES 345RSOBK • 345RSOWWPage 15GARANTIEBROAN-NUTONE LLC – Garantie exclusive limitée – Le contrat de garantie exclusive limitée (la « Garantie »

Page 8

MODÈLES 345RSOBK • 345RSOWWPage 1679040169C

Page 9 - AMONTER SUR LE TOIT

MODELOS 345RSOBK • 345RSOWWPágina 17ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS

Page 10 - INSTALLATION

MODELOS 345RSOBK • 345RSOWWPágina 185. Desde el interior del ático, encuentre la ubicación deseada para el ventilador y marque un punto a la mitad

Page 11 - MODÈLES 345RSOBK • 345RSOWW

MODELOS 345RSOBK • 345RSOWWPágina 198. Recorte las tejas dentro del círculo.9. Usando el mismo clavo y el cordón indicados en el paso 6, marque un

Page 12

MODELS 345RSOBK • 345RSOWWPage 25. Working from the inside of your attic, find the desired ventilator location and mark a spot halfway between raft

Page 13 - PANNEAUSOLAIRE

MODELOS 345RSOBK • 345RSOWWPágina 2014. Asegúrese de que la base del ventilador esté paralela a la saliente del techo, y con cuidado levante las tej

Page 14 - PIÈCES DE RECHANGE

MODELOS 345RSOBK • 345RSOWWPágina 211 7. Desde el interior del ático, encuentre el centro de la ubicación seleccionada para el panel solar identific

Page 15 - GARANTIE

MODELOS 345RSOBK • 345RSOWWPágina 22Modelo Modelo Clave 345RSOBK 345RSOWW Descripción N.o (Negro) (Madera curtida) 1 77001317 77001318 Con

Page 16

MODELOS 345RSOBK • 345RSOWWPágina 23GARANTÍABROAN-NUTONE LLC – Garantía limitada exclusiva –El Convenio de Garantía Limitada Exclusiva (la "Ga

Page 17 - MONTAJE EN EL TECHO

MODELOS 345RSOBK • 345RSOWWPágina 2479040169C

Page 18 - INSTALACIÓN

MODELS 345RSOBK • 345RSOWWPage 38. Cut out the shingles inside of the circle.9. Using the same nail and string shown in step 6, scribe a 14” diame

Page 19 - Página 19

MODELS 345RSOBK • 345RSOWWPage 414. Make sure the ventilator base is parallel to the roof ridge, carefully lift shingles and nail or screw base secu

Page 20 - Página 20

MODELS 345RSOBK • 345RSOWWPage 51 7. Working from inside the attic, find the center of the selected solar panel location identified in step 2, drill

Page 21 - SOLARREMOTO

MODELS 345RSOBK • 345RSOWWPage 6Model Model Key 345RSOBK 345RSOWW Description No. (Black) (Weathered Wood) 1 77001317 77001318 Solar Panel

Page 22 - PIEZAS DE SERVICIO

MODELS 345RSOBK • 345RSOWWPage 7WARRANTYBROAN-NUTONE LLC – Exclusive Limited Warranty –The Exclusive Limited Warranty Agreement (the “Warranty”) is

Page 23 - GARANTÍA

MODELS 345RSOBK • 345RSOWWPage 879040169C

Page 24 - Página 24

MODÈLES 345RSOBK • 345RSOWWPage 9AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQU

Commentaires sur ces manuels

Pas de commentaire