MODELS 345GOBK • 345GOWW
Page 1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, disable the ventilator by cover-
ing the solar panel with cardboard or disconnecting the wires
from the motor terminals (note wire locations when disconnect-
ing).
3. Installation work must be done by a qualified person(s) in ac-
cordance with all applicable codes and standards, including
fire-rated construction codes and standards.
4. If removing an existing 120 VAC powered attic ventilator, use
only a qualified person(s) to remove any electrical wiring in
accordance with all applicable codes and standards.
5. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment manufac-
turer's guidelines and safety standards such as those published
by the National Fire Protection Association (NFPA), and the
American Society for Heating, Refrigeration and Air Condition-
ing Engineers (ASHRAE), and the local code authorities.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
CAUTION
1. For general ventilating use only. Do not use to exhaust hazardous
or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. This unit has an unguarded impeller. Do not use in locations
readily accessible to people or animals.
4. This ventilator operates when the solar panel is exposed to sun
light. To reduce risk of injury while installing, servicing or clean-
ing unit, cover the solar panel with cardboard or disconnect the
wires from the motor terminals (note wire locations when dis-
connecting).
5. The recommended open air inlet for this ventilator is 2 square
feet. The best location for these air intake vents are under the
eaves with direct access to the attic. Failure to provide these
intakes could cause natural-draft gas appliances to backdraft.
6. Your attic fan installation will create a screened opening into
your attic space. During a heavy rain storm there could be a
light spray of rain into this attic space. This is a normal condition
with all attic ventilators and will not cause any damage to the
structure. We recommend that you do not store any valuable
articles directly under the fan opening in the roof.
7. This ventilator is intended for gable (side wall) installation. Broan
Models 345, 349, 350, 355, & 356 Roof Mount Ventilators are
available for roof applications.
8. This ventilator is suitable for use with Broan Model 433 Auto-
matic Shutter (purchase separately).
9. This ventilator includes a permanently lubricated motor. Do not
oil or disassemble.
10. The installation instructions contained in this document are only
a recommendation and individual professionals may have their
own methods of installation. If your roof has an existing war-
ranty, installation of this product by anyone other than those
who installed the roof may jeopardize any future warranty claim.
Please check with the original installer of your roof if this is a
concern.
11. When working with asphalt shingles in cold weather (below
40
o
F), take care to avoid damage to the shingle edges and cor-
ners.
12. For installations in climates where cold weather condensation
is not a concern, Broan Model CWT45 thermostat is available.
It disconnects power to the motor when the temperature drops
below 50
o
F. Power is applied to the motor when the temperature
reaches 61
o
F.
GABLE-MOUNT
SOLAR POWERED
ATTIC VENTILATOR
READ AND SAVE THESE INSTRUCTIONS
r
Slotted Screwdriver
r
Drill
r
1/4" Drill Bit
r
Sabre Saw or Keyhole Saw
r
Saw
r
Hammer
r
Ruler / Tape Measure
r
Pencil, Marker or Scribe
r
Utility Knife
r
Silicone or Roofing Cement
r
Galvanized Roofing Nails (1¾" min.)
TOOLS AND MATERIALS REQUIRED
Register your product online at:
www.broan.com/register
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - ATTIC VENTILATOR

MODELS 345GOBK • 345GOWWPage 1WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:1. Use this unit

Page 2 - VENTILATOR INSTALLATION

MODELOS 345GOBK • 345GOWWPágina 10INSTALACIÓN DEL VENTILADOR Nota: Este ventilador tiene capacidad para reemplazar un ventilador para ático existente

Page 3 - SERVICE PARTS

MODELOS 345GOBK • 345GOWWPágina 116. Desde el interior del ático, encuentre el centro de la ubicación seleccionada para el panel solar identificada e

Page 4 - WARRANTY

MODELOS 345GOBK • 345GOWWPágina 12GARANTÍABROAN-NUTONE LLC – Garantía limitada exclusiva –El Convenio de Garantía Limitada Exclusiva (la "Garant

Page 5 - MONTER SUR LE PIGNON

MODELS 345GOBK • 345GOWWPage 2VENTILATOR INSTALLATIONNote: This ventilator is capable of replacing an existing 120 volt powered attic ventilator. O

Page 6 - INSTALLATION DU VENTILATEUR

MODELS 345GOBK • 345GOWWPage 36. Working from inside the attic, find the center of the selected solar panel location identified in step 2, drill a

Page 7 - PIÈCES DE RECHANGE

MODELS 345GOBK • 345GOWWPage 4WARRANTYBROAN-NUTONE LLC – Exclusive Limited Warranty –The Exclusive Limited Warranty Agreement (the “Warranty”) is en

Page 8 - GARANTIE

MODÈLES 345GOBK • 345GOWWPage 5AVERTISSEMENT OBSERVEZ LES DIRECTIVES CI-DESSOUS AFIN DE RÉDUIRE LES RISQUES D'INCENDIE, DE CHOC ÉLECTRIQUE OU

Page 9 - EN HASTIAL

MODÈLES 345GOBK • 345GOWWPage 6INSTALLATION DU VENTILATEUR Remarque : Ce ventilateur peut remplacer un ventila-teur électrique de 120 volts pour

Page 10 - INSTALACIÓN DEL VENTILADOR

MODÈLES 345GOBK • 345GOWWPage 76. De l’intérieur du grenier, trouvez le centre de l’emplacement choisi à l’étape 2 pour le panneau solaire et percez

Page 11 - PIEZAS DE SERVICIO

MODÈLES 345GOBK • 345GOWWPage 8GARANTIEBROAN-NUTONE LLC – Garantie exclusive limitée – Le contrat de garantie exclusive limitée (la « Garantie ») est

Page 12 - GARANTÍA

MODELOS 345GOBK • 345GOWWPágina 9ADVERTENCIA PARA REDUCIR EL RIESGO DE INCENDIOS, DESCARGAS ELÉCTRICAS O LESIONES PERSONALES, SIGA LAS

Commentaires sur ces manuels

Pas de commentaire