INSTALLATION MANUAL
INSTALLATION
7
For ADA compliance installation guidelines, please visit www.broan-nutone.com
Recommended Tools and Accessories
for Installation
• Measuring tape
Phillips screwdriver no. 2
Nut driver or socket 11/32”
Flat blade screwdriver (to open knockout holes)
Drill, 1/8” drill bit and 1½” hole saw (to mark holes for ducting and cut electrical access hole)
7/64” drill bit (to drill holes for EZ1 brackets mounting screws)
Wood shims (2) and wood screws (4) (required for standard installation to framed cabinet)
Saw (to cut holes for ducted application)
Sheet metal shears (ducted installation only, for duct adjustment)
Pliers (ducted installation only, for duct adjustment)
Metal foil duct tape (for ducted applications)
Scissors (to cut metal foil duct tape)
• Pencil
• Wire stripper
Strain relief, 1/2” diameter (to secure house wiring cable to the hood)
Install Ductwork (Ducted Installations Only)
SOFFIT
18" MIN - 24" MAX
ABOVE
COOKING SURFACE
CABINET
3¼" X 10" OR
3¼" X 14" DUCT
(FOR HORIZONTAL DISCHARGE)
WALL CAP
ROOF CAP
3¼" X 10", 3¼" X 14" OR
7" ROUND DUCT
(FOR VERTICAL
DISCHARGE
)
HOUSE WIRING
(TOP OR BACK OF HOOD)
HOOD
NOTE: Distances over 24” are at the installer and user discretion.
1 ] Determine whether hood will discharge vertically (3¼” x 10”, 3¼” x 14” or 7” round),
or horizontally (3¼” x 10” or 3¼” x 14” only).
2 ] Decide where the ductwork will run between the hood and the outdoors.
3 ] Choose a straight, short duct run to allow the hood to perform most efficiently. Long duct
runs, elbows and transitions will reduce the performance of the hood. Use as few of them as
possible. When possible, use at least 2 foot straight runs before any turns. Larger ductwork
may be required for best performance with longer duct runs.
4 ] Install wall cap or roof cap (sold separately); ensure there is no leak in house insulation.
Connect metal ductwork to cap and work back towards the hood location. Use 2” metal foil