Broan BCDJ136BL Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Non Broan BCDJ136BL. Broan BCDJ136BL BCDJ Additional Info Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 15
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
ADA LOW VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS (PAGE 1 AND 2)
AND DOUBLE BLOWER RANGE HOODS (PAGE 3 TO 5)
WARNING
VQ0010
!
For residential (domestic) installation only. Before proceeding, switch power off at service panel and lock service disconnecting
means to prevent power from being switched on accidentally. Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. Also,
it is recommended to wear safety glasses and gloves.
B Remove filters from the hood and set them aside.
C Remove the wiring cover (shaded part in illustration below) retaining
screw. Slide the wiring cover out of the hood and set it aside with its
screw.
D Unplug the blower connector from the main harness.
NOTE: The illustrations in this procedure are generic; some hood details may slightly differ from the hood you have on hand but the procedure itself applies
to all single blower range hoods listed in this document (see page 2).
HD0737
Wiring cover
screw
E Using a 11/32'' socket, remove the 6 nuts retaining the blower
chamber to the hood assembly (2 nuts on inner back and 2 other nuts
per sides), then use a Phillips no. 2 screwdriver to remove both front
corner screws. See picture below for nuts and screws locations. Pull
the blower chamber out of the hood assembly and set it aside with its
retaining screws and nuts.
HE0253
HD0672
Nuts
Nuts
Screw
F Remove and set aside the 4 front screws retaining the control access
panel to the hood.
HD0673
Screw locations
G Fold back the control access panel to access the control panel connections.
HD0674
99045883B
H Measure 4 feet from the connector end of the provided ADA cable
and cut the cable. Set aside the remaining 15-ft. cable section without
connector; it will be used later (refer to step N). Run the connector of the
ADA cable section through the wiring cable hole on the bent plate.
HE0274
I Connect the ADA cable connector to the 6-pin connector on control
board (circled on picture below).
HE0288
CAUTION
Use exclusively the cable included in this kit.
J Secure the ADA cable section to the main harness using a tie-wrap.
HD0952
Tie-wrap
Vue de la page 0
1 2 3 4 5 6 ... 14 15

Résumé du contenu

Page 1 - WARNING

1ADA LOW VOLTAGE WIRING INSTRUCTIONS FOR SINGLE BLOWER RANGE HOODS (PAGE 1 AND 2) AND DOUBLE BLOWER RANGE HOODS (PAGE 3 TO 5) WARNINGVQ0010!For resi

Page 2 - RANGE HOOD OPERATION

10HD0958H Placer les connexions avec capuchon dans la base de la boîte de connexion, puis bien installer le couvercle en veillant à ce que le câble co

Page 3

11INSTRUCCIONES DE CABLEADO DE BAJA TENSIÓN CONFORMEMENTE A LAS NORMAS ADA PARA CAMPANAS DE COCINA DE UN SOLO VENTILADOR (PÁGINAS 1 Y 2) Y DE DOS VENT

Page 4 - ADA CAbLE CONNECTIONS

12ESTE PROCEDImIENTO SE APLICA A LAS SIGUIENTES SERIES DE CAmPANAS DE COCINASerie Broan: BCDF, BKDB, BCDA, BKDD, BKDEG, BKDF, CLDA, CRDEG, BNDD,

Page 5

13INSTRUCCIONES DE CABLEADO DE BAJA TENSIÓN CONFORMEMENTE A LAS NORMAS ADA PARA CAMPANAS DE COCINA DE DOS VENTILADORES ADVERTENCIAVQ0010!Para instal

Page 6 - AVERTISSEMENT

14TODAS LAS OTRAS SERIES DE CAmPANAS DE COCINAACCESO AL GRUPO DE CAbLES PRINCIPAL DE LA CAmPANA (CONT.) Retire los filtros de la campana y póngalos a

Page 7 - Commande

15HD0958H Coloque las tuercas para alambre dentro de la base de la caja de conexiones y encaje la tapa de la caja sobre su base, asegurándose de que e

Page 8 - VENTILATEUR DOUBLE

2THIS PROCEDURE APPLIES TO THE FOLLOWING RANGE HOOD SERIESBroan Series: BCDF, BKDB, BCDA, BKDD, BKDEG, BKDF, CLDA, CRDEG, BNDD, BNDF and BQDD.Nu

Page 9 - ATTENTION

3ADA LOW VOLTAGE WIRING INSTRUCTIONS FOR DOUBLE BLOWER RANGE HOODS WARNINGVQ0010!For residential (domestic) installation only. Before proceeding, sw

Page 10 - FONCTIONNEmENT DE LA HOTTE

4ALL OTHER RANGE HOOD SERIESACCESS TO RANGE HOOD mAIN HARNESS (CONT’D) Remove filters from the hood and set them aside.  Using a 11/32” nutdriver o

Page 11 - ADVERTENCIA

5HD0958H Put the wire nuts inside the connection box base, then snap the connection box lid on its base, ensuring the ADA cable runs through the open

Page 12 - ATENCIÓN

6INSTRUCTIONS DE CÂBLAGE BASSE TENSION CONFORME À L’ADA POUR HOTTES À VENTILATEUR SIMPLE (PAGES 1 ET 2) ET HOTTES À VENTILATEUR DOUBLE (PAGES 3 À 5)

Page 13

7CETTE PROCÉDURE S’APPLIQUE AUX HOTTES À VENTILATEUR SImPLE SUIVANTES :Série Broan : BCDF, BKDB, BCDA, BKDD, BKDEG, BKDF, CLDA, CRDEG, BNDD, BNDF et

Page 14 - CONEXIONES DEL CAbLE ADA

8INSTRUCTIONS DE CÂBLAGE BASSE TENSION CONFORME À L’ADA POUR HOTTES À VENTILATEUR DOUBLE AVERTISSEMENTVQ0010!Pour installation résidentielle (domest

Page 15

9TOUTES AUTRES SÉRIES DE HOTTESACCèS AU FAISCEAU DE FILS PRINCIPAL DE LA HOTTE (SUITE) Retirer les filtres de la hotte et les mettre de côté.  À l