Broan PME300 Guide d'installation Page 2

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 1
CONNECT DUCTWORK
1. Take the damper and assemble it onto the hood’s discharge
opening, pressing slightly.
2. Use 6" round metal duct to connect the discharge collar on the
hood to the ductwork above.
3. Use duct tape to make all joints secure and air tight.
WIRING
Note: This range hood must be properly grounded.
The unit should be installed by a qualified electrician in accor-
dance with all applicable national and local electrical codes.
1. Remove the wiring box cover by removing three screws. Remove
a knockout from the wiring box.
2. Secure the conduit to the wiring box through a conduit connec-
tor.
3. Make electrical connections. Connect white to white, black to
black and green to green.
4. Replace wiring box cover and screws. Make sure that wires are
not pinched between cover and box.
INSTALL THE DUCTWORK
NOTE: To reduce the risk of fire, use only metal ductwork.
1. Decide where the ductwork will run between the hood and the
outside (Refer to Figure 1).
2. A straight, short duct run will allow the hood to perform most effi-
ciently.
3. Long duct runs, elbows, and transitions will reduce the performance
of the hood. Use as few of them as possible. Larger ducting may
be required for best performance with longer duct runs.
4. Install a roof or wall cap. Connect round metal ductwork to cap
and work back towards hood location. Use duct tape to seal the
joints between ductwork sections.
INSTALL THE HOOD
NOTE: the hood has to be installed, inside the cabinet.
The internal height of cabinet has to be minimum 16”.
The hood should be mounted centered over the cook top burners.
1. Remove the grid by moving the 2 slide fasteners “A” forward
(Fig.2). Push the filter latch in and tilt the filters downward and
remove (Fig. 2B).
2. Cut a hole in the bottom of the cabinet, using the dimensions
shown (Fig. 3).
3. Adjust the position of the clasping side spring by means of the
proper “B” screw according to the thickness of the board panel to
which it is going to be anchored (Fig. 4).
4. NOTE: For installations where the Power Pack is less than 30”
above cook top, it is recommended that the Power Pack be mounted
into a metal liner or non-combustible material. This will allow easier
cleaning and provide protection to the cabinetry (Fig.5A).
5. Insert the hood in the cabinet (Fig. 5) or metal liner (Fig. 5A) and
lock in place by means of the side spring.
6. Secure the hood with the (4) “C” mounting sheet metal screws.
(Fig. 5 - wood bottom installation; recommended thickness 1/2”-
3/4”).
(For alternate mounting, use machine screws with washers and
nuts. This alternate mounting method needs to be done prior to
installation of metal liner).
7. Replace the grid by moving the 2 slide fasteners “A” backward
(Fig.2).
ROOF CAP
ROUND
DUCT
WALL
CAP
6”
ROUND
ELBOW
24” TO 30” ABOVE
COOKING SURFACE
CUT A HOLE IN THE BOTTOM OF
THE CABINET
10-1/4”
19-1/2”
POWER
MODULE
min 7/16”
max 13/16
B
FIG. 1
FIG. 2 FIG. 3
FIG. 4
FIG. 5 FIG.5A
METAL LINER
WIRING BOX
FIG. 6
Vue de la page 1
1 2 3 4 5 6 7 8

Commentaires sur ces manuels